제목콘크리트 충전형 합성기둥의 유효휨강성 설계기준에 대한 고찰2018-10-30 14:51
카테고리합성구조
작성자 Level 1
첨부파일KSSC_4_2014_06_017(C).pdf (481.6KB)

콘크리트 충전형 합성기둥의 유효휨강성 설계기준에 대한 고찰 


Code Review on Effective Stiffness Provision of Concrete-Filled Steel Tube Column 


김 승 원1)*

Kim, Seung Weon


ABSTRACT: The effective flexural stiffness of cross section of concrete filled tube column is used for compression 

strength design of long column, stability analysis and lateral load analysis of frame. Because both elastic modulus of 

concrete and efficient coefficient of composite section among national code are different, the effective flexural stiffness 

of composite section would be different. In this paper, effective flexural stiffness of composite section by each code was 

compared with the experimental data of other researcher.